Commercial Sign Permit Drawings Requirements & Building Number Heights
Required Drawings for a Sign Permit
Every commercial sign permit application requires a drawing set that shows reviewers exactly what you intend to install and where. A complete set typically includes a scaled elevation drawing of the sign face, a site plan showing the sign's location relative to property lines and the right-of-way, structural details for the footing and support, and electrical wiring diagrams for any illuminated sign.
Reviewers check these drawings against the dimensional limits in the local sign ordinance — height, area, and setback. Drawings that omit any of these elements, or that lack clearly labeled dimensions, are the most common cause of correction cycles that add weeks to the approval timeline.
Scaled Elevation Drawings
The elevation drawing shows the sign face as it will appear from the street, drawn to a defined scale (typically 1:20 or larger). It must dimension the overall sign height and width, the sign area calculation, the height above finished grade for freestanding signs, and the height above the roofline for wall-mounted signs.
For channel-letter signs, show the smallest rectangle enclosing all letters together rather than measuring each letter individually, unless your local code specifies otherwise. Label the area calculation directly on the drawing so the reviewer can verify it against the district cap without re-computing.
Site Plans and Setback Dimensions
The site plan shows the sign's location on the property and its relationship to the property line, the public right-of-way, and any nearby intersections or driveways. For freestanding signs, dimension the setback from the nearest property line to the nearest edge of the sign structure.
Setback is one of the most frequently checked parameters because it affects driver sight lines. A site plan that does not clearly dimension the setback will almost always be returned for correction. If the required setback pushes the sign out of the desired location, revise the plan before submitting.
Building Number Height and Address Sign Standards
Many municipal codes include separate standards for building address numbers, which are often regulated as a distinct sign type. These rules typically specify a minimum character height for address numbers based on the distance from the street to the building, ensuring visibility for emergency responders and delivery services.
A common standard requires address numbers at least 6 inches tall for buildings within 50 feet of the street, scaling up to 12 inches or more for buildings set further back. Some codes also require address numbers to be illuminated and to contrast with their background. Always check the address-number section of your local code, as it is frequently separate from the general sign ordinance.